BPDFV - E-824, ELMER'S REDI SPACK

  • MSDS: BPDFV
  • Manufacturer: BORDEN INC
  • Product Name: E-824, ELMER'S REDI SPACK
  • National Stock Number: 8030-00N029902
Product Identification

Product ID:E-824, ELMER'S REDI SPACK
MSDS Date:12/11/1986
FSC:8030
NIIN:00N029902
MSDS Number: BPDFV

Responsible Party
BORDEN INC
180 EAST BROAD ST
COLUMBUS, OH 43215
US

Emergency Phone: 614-431-6600

Info Phone: 614-431-6680; 800-848-9400

Cage: 07982

Contractor
BORDEN INC
208 COLUMBUS, OH 43215-3705 US

Telephone: 614-225-6124

Cage: 07982

Ingredients

1); (CALCIUM CARBONATE)

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: >50%

OSHA PEL 15MG/M3 TDUST;5RDUST

ACGIH TLV: 10 MG/M3 TDUST


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 1-5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


TALC (POWDER), CONTAINING NO ASBESTOS FIBERS, (TALC)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 5-15%

OSHA PEL 2 MG/M3 RDUST

ACGIH TLV: 2 MG/M3 RDUST


USE OF PERSONAL PROT EQUIP & PRUDENT WORK

RTECS: 9999999ZZ


ALL ISSUES PERTAINING TO YOUR OPS. WE, THEREFORE REC

RTECS: 9999999ZZ


WHETHER OR NOT YOUR PROGRAMS ARE ADEQUATE.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN ABSORP: NOT TOX DERMALLY
WHEN TESTED AS DESCRIBED IN 16-CFR PART 1500.3 (C) (1) AND (2).
INGEST: NOT TOXIC ORALLY WHEN TESTED AS DESCRIBED IN 16 CFR PART
1500.3 (C) (1) AND (2) . INHAL: MAY BE HARMFUL IF INHALED. VAP CAN
CAUSE IRRIT OF NOSE, THROAT & LUNGS. SKIN: NOT AN IRRITANT WHEN
(EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: TESTED AS DECRIBED IN 16 CFR PART
1500.41. EYES: NOT AN IRRITANT WHEN TESTED AS DESCRIBED IN 16 CFR
PART 1500.42. CHRONIC: OVEREXPOSURE MAY CAUSE LUNG DAMAGE OR LUNG
FIBROSIS.
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY DISORDERS
MAY BE AGGRAVATED BY EXPOSURE.

First Aid

First Aid:INGEST:IF ACCIDENTALLY SWALLOWED, DILUTE BY DRINKING LG QTYS
OF WATER. IMMED CONT POIS CNTRL CNTR/HOSPITAL EMER ROOM FOR ANY
OTHER ADDITIONAL TREATMENT DIRECTIONS. INHAL:REMOVE TO FRESH AIR.
IF NOT BR THG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF BRTHG IS
DFCLT, GIVE O2.CALL MD. EYE:FLUSH THORO W/WATER FOR AT LEAST 15
MIN.IF IRRIT PERSISTS, CALL MD.SKIN:FLUSH W/COPIOUS AMTS OF WATER
.CALL MD

Fire Fighting

Extinguishing Media:USE WATER SPRAY, DRY CHEMICAL, FOAM OR CO2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WILL NOT BURN UNLESS WATER HAS EVAPORATED.
USE WATER TO KEEP FIRE-EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:SWEEP (SCOOP) UP AND REMOVE. PREVENT ENTRY
INTO NATURAL BODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE IN A
COOL, DRY PLACE.
Other Precautions:AVOID BREATHING VAPOR. USE WITH ADEQUATE VENTILATION.
HANDLE I/A/W GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICES. THESE
PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE AND REMOVAL OF THE
MATERIAL FROM EYES, SKIN AND CLOTHING.

Exposure Controls

Respiratory Protection:WHERE AIR CONTAMINANTS CAN EXCEED ACCEPTABLE
CRITERIA, USE NIOSH/MSHA APPRVD RESP PROT EQUIP. RESPIRATORS SHOULD
BE SELECTED BASED ON FORM & CONC OF CONTAMINANTS IN AIR I/A/W OSHA
29 CFR 1910.134/OTHE R APPLIC STANDARDS/GUIDELINES.
Ventilation:IF AIRBORNE CONTAMINANTS ARE GENERATED WHEN MATL IS HEATED/
HANDLED, SUFFICIENT VENT IN VOL & AIR FLOW (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
RESP PROT: PATTERNS SHOULD BE PROVIDED TO KEEP AIR CONTAMINANT CONC
LVLS BELOW ACCCEPTABLE CRITERIA. ENGINEERING CONTROLS: THE
FOLLOWING EXPOS CONTROL TECHNIQUES MAY BE USED TO EFFECTIVELY
MINIMIZE EM PLOYEE EXPOS: LOC EXHST VENT, ENCLOSED SYS DESIGN,
PROCESS ISOLATION & REMOTE CONTROL IN COMBINATION W/APPROP (ING 4)

Chemical Properties

HCC:N1
Spec Gravity:1.6
Appearance and Odor:WHITE PUTTY; MILD ACRYLIC ODOR
Percent Volatiles by Volume:22

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE, AND
FEDERAL REQUIRMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.